Case Study

Acoustic Walls for Gas Turbine Power Plant

Acoustic wall noise barrier used in industrial setting, reducing environmental noise pollution.
Burgess manning acoustic barrier.

Customer Challenge:

A peaking power plant served by gas turbines required noise mitigation measures to limit emissions at the site boundary and comply with local regulations.

Solution:

A series of 10m and 12m high acoustic walls, with an overall length of 300m, strategically located around the site in order to provide protection to nearby areas:

  • Acoustically absorbent panels: Panels faced with perforated steel sheet to one side to avoid reflective noise issues.
  • Support structure design: Singular column design with detailed calculation to reduce the support structure footprint while ensuring stability against wind and earthquake loads.
  • Installation provision: Integrated lifting points for quick and safe installation.
  • Durable finish: Durable ISO12944 C5 finish for long-term outdoor performance.

Outcome: