Static Filtration
Multi-stage air intake filtration that protects turbomachinery in the world’s harshest environments
Clean intake air is the first line of defense for any gas turbine, compressor or engine. Burgess-Manning static filtration systems remove dust, moisture, salt, hydrocarbons and industrial pollution from combustion and ventilation air before it reaches your rotating equipment. The result is sustained performance, lower maintenance and a longer service life even in continental, offshore, tropical and cold-climate sites.
A static filtration system is a fixed, multi-stage air filter house that cleans the air entering turbomachinery. Unlike self-cleaning (pulse) systems, the filter elements stay in place and capture contaminants until they are replaced. This makes static filtration the preferred choice where the priority is the highest final air quality and protection against moisture, salt and sticky or oily contaminants.
Air passes through progressive stages, from coarse to fine: inlet weather protection, pre-filters, fine filters and a high-efficiency final barrier. Each stage protects the next, so the system holds a low, stable pressure drop and a long service life between filter changes.
Industries:
- Power generation
- Oil & gas (onshore and offshore)
- LNG and gas transmission / compressor stations
- Petrochemical and refining
- Industrial cogeneration
Systems and Conditions:
- Gas turbine combustion air intake systems
- Compressor and engine air intakes
- Enclosure and engine-hall ventilation air
- Harsh environments: marine / salt-laden, desert, arctic and humid tropical
- Sites where high final filtration efficiency and corrosion protection are critical
Minimum Information Required For Getting A Quote
- Air flow rate (m³/h or ACFM)
- Turbine / compressor / engine make and model
- Site conditions: climate, altitude, dust load, salt and humidity exposure
- Required filtration class or target final efficiency
- Available footprint and orientation constraints
- Material, coating and corrosion-class requirements
- Applicable design codes and certifications
- Acoustic / noise requirements (if combined with intake silencing)
Filtration Principles:
Burgess-Manning static filter houses use a multi-stage arrangement to balance the three factors that determine intake filter performance: filtration efficiency (how clean the air is), dust-holding capacity (how long the filter lasts before changeout) and pressure drop (the energy penalty the turbine pays to draw air through the filter). Stripping out coarse particles early keeps the high-efficiency final stage clean, which protects turbine output and extends filter life.
Why it matters: Fine particles that reach the compressor cause fouling of the blades, gradually reducing output and efficiency, while salt and reactive contaminants cause hot corrosion. A high-efficiency final filter stage keeps blades clean and helps prevent unplanned shutdowns.
Product Features and Benefits:
- High final filtration efficiency up to E12 / MERV 16
- High dust-holding capacity
- Low, stable pressure drop
- Corrosion & salt protection
- Airtight filter banks
- Modular & quick to assemble
- Fully configurable
Design Codes and Standards:
Air intake filter elements for rotating equipment are classified under ISO 16890 (fine-dust efficiency, ePM1 / ePM2.5 / ePM10) and tested under ISO 29461 (air intake filter systems for rotary machinery). High-efficiency filter elements are available according to EPA/HEPA (EN 1822 / ISO 29463) and ASHRAE MERV (52.2).
Options:
- Weather hoods, louvers and drift / droplet eliminators
- Bird and insect screens
- Inertial pre-filters with dust extraction for high-dust sites
- Anti-icing systems for cold climates
- Evaporative cooling
- Motorized dampers or roller shutters for intake isolation
- Differential-pressure monitoring and instrumentation
- Support structure, platforms and access
- Stainless steel or upgraded coating systems for corrosive environments
STATIC FILTRATION OR JET-PULSE, WHICH DO I NEED?
Not sure which fits your site? See Jet-Pulse Filtration or talk to a Burgess-Manning engineer about your air quality and dust load.
| BEST FOR | High, dry dust loads like desert, sandstorm, laterite and arid sites | Moisture, salt and sticky/oily contaminants; highest final air quality |
| CLEANING | Automatic compressed-air pulse, in place | None; elements replaced when loaded |
| PRESSURE DROP | Low and stable over service life | Rises as the filter loads with dust |
| MAINTENANCE | Fewer changeouts in heavy dust | Scheduled element replacement |
Relevant Industries
Static Filtration FAQ
Related Products
Make every area of your facility quieter, safer and compliant. Explore all Burgess-Manning noise reduction products.