Custom Vent Silencers
Fully customized noise control solutions for pressurized gas applications
Vent silencers are used to control the very high noise levels associated with venting pressurized gases to the atmosphere, such as steam, natural gas, air, hydrogen, oxygen, nitrogen or any other combination of compressed gases.
Burgess-Manning vent silencers are typically installed on relief, safety, control or start-up valves in steam boilers, HRSGs, gas compressing stations, FPSOs and most oil, gas and chemical processing plants. They are also used in any industry where compressed gases are utilized.
Custom vent silencers have been developed to address the needs of highly demanding customers that wants to specify everything, sometimes above code requirements: process and design conditions of course, but also materials, welding processes, NDE extent, extensive documentation for review and approval, or inspections. Silencers have to follow a lot of different specifications, resulting in a specific project management and quality process. With our highly qualified personnel all over the world, Burgess Manning has an extensive knowledge of the main Blue Chip or EPC customers’ requirements and the flexibility to adapt our manufacturing process according to the most improbable wishes.
Custom vent silencers are engineered to meet project-specific requirements, often exceeding standard code and documentation levels. Project timelines are therefore driven by the level of customization, including engineering scope, material selection, fabrication requirements, documentation, inspections and approval cycles. A dedicated preliminary engineering phase ensures that all requirements are clearly defined and validated before fabrication begins. The result is a vent silencer solution that fully complies with your technical, operational and project requirements.
Minimum Information Required For Getting A Quote
- Fluid type: steam, air, oxygen, hydrogen, nitrogen, natural gas, … IN case of specific mix, we need the detailed composition of the mix
- Mass Flow rate
- Valve upstream pressure and temperature
- Inlet diameter
- Max allowable pressure drops
- Silenced noise requirement or required attenuation
- Options required
Acoustic Principles:
- Transformative and Absorptive
Product Features & Benefits:
- Guaranteed acoustic performance, up to 60 dBA attenuation
- Guaranteed max pressure drop
- Suitable for all kinds of flow rates, pressures and temperatures
Design:
- Cylindrical and rectangular design
- Fully welded construction
- Fixed or sliding inlet connections
- Single or multiple inlets
- Side or Bottom supporting brackets
- Inlet diameter: no limits
- Casing diameter: no limits
- Max Design Pressure: As per materials specs
- Max Design temperature: As per materials specs
- Materials: Carbon steel, Stainless steel, P11, P22, P91 and any other metal.
Design Codes:
- ASME B31.1
- ASME B31.3
- ASME B31.8
- ASME VIII Div 1
- EN 13480
- EN13445
Certifications:
- PED 14/68/EC
- UKCA
Options:
- Sliding or fixed connections
- Single or multiple inlets
- Flanged or butt weld connection
- Self-support, bottom support, side support
- Bird screen
- Rain, snow or sand hood
- Elbow
- Roof passage
- Restrictive Orifice (RO)
- Toroidal Ring (for hydrogen service)
- Instrumentation
- Liquid sump
- Etc.
Documentation:
- As per agreed Vendor Document List
Temporary Vent Down Usage
- Steam
- Air
Enhanced Noise Attenuation
- Up to 50+ dB
RENTAL OPTIONS
Burgess-Manning offers rental options for short-term commissioning projects (weeks to months).
Relevant Industries
Related Products
Make every area of your facility quieter, safer and compliant. Explore all Burgess-Manning noise reduction products.